11U Server Cabinet Model PSEi1111U Server Cabinet
Model PSEi11

Air-cooled acoustic server rack enclosure with on board remote management system

The PSEi11 Kell Systems ComputerVault Pro RM is a quiet 11U server cabinet that offers the full physical environment and feature set of the ComputerVault Pro PSE12 range of server enclosures but comes with a powerful 1U-environmental monitoring and remote power management system built in.

The PSEi11 acoustic rack features advanced sound proofing which results in virtually silent operation. This is combined with a feature-rich remote management pack that enables companies to deploy servers and network infrastructure direct in the working office at local sites, and manage the core IT functions remotely

ComputerVault Pro RM remotely monitors rack temperatures, humidity, enclosure fan speeds, UPS status and can detect unauthorised cabinet access triggering an alert system to give advance warning of potential environmental or security problems.

Its comprehensive remote power management functions enable the systems administrator to switch individual devices on/off in each rack at any site.


Physical capacity: 11 rack spaces
Noise reduction: 18.5 dB
Max. recommended thermal load: 1.2 kW
Integrated power distribution: 11 x remote-managed outlets
Power consumption: 19 Watts


Full Specifications

External dimensions:

Height 750 mm / 29.5" x Width 750 mm / 29.5" x Depth 1130 mm / 44.5"

Weight:

119 kg / 262 lbs

Physical rack capacity:

11 x EIA 1¾" / 44.5 mm rack spaces
4-post rack, fully EIA-compliant, with fixed rear posts and adjustable front posts
Rack depth 800 mm / 31.5", adjustable down to 720 mm / 28.3"
(option for baying kit to link cabinets together, part code BK12)

Extra internal cabinet depth:

Forward of the front rack posts: 100 mm / 4" space for front frame cabling/patching
(see Technical Drawings section)

Rearward of the rear rack posts: 60 mm / 2" except where fan modules intrude
(see Technical Drawings section)

Floor space requirements:

Individual cabinets are designed to be pushed back flush against a wall. An air space of 200 mm / 8" on both sides of the cabinet is essential for normal operation.

Baying cabinets together:

Baying kit option available. The easy-to-fit baying kit maintains the soundproof seal but opens adjacent cabinets onto each other internally.

Special notes on baying:
1: Unlike single cabinets, bayed cabinets cannot be pushed fully back against a wall. Air space of
100 mm / 6" behind the cabinet is essential for normal operation.
2: Baying model PSEi11 cabinets together reduces the maximum recommended thermal load in each cabinet from 1.2 kW to 1 kW.
3: In bayed cabinets, it is essential that the thermal load is distributed evenly between the cabinets.

Cooling system:

1 x Kell Systems ultra-low-noise exhaust fan module
1.2 kW maximum recommended total thermal load inside the cabinet

Power consumption:

19 Watts total power consumption by the PSEi11 itself, including cooling system

Noise of PSEi11 itself:

40.5 dBA total noise generated by PSEi11, measured 1.0 m / 39" in front of the cabinet

Noise reduction:

18.5 dB broadband noise reduction, measured 1.0 m / 39" in front of the cabinet
(HP and Dell servers used as noise source in noise reduction measurements)

Mobility:

4 x heavy duty castor-type wheels
Front wheels have 360° rotation for steerability
Rear wheels have fixed front-to-back motion for stability

Rear and side access:

Detachable rear side panels, left and right, for installation and maintenance access
Detachable rear fan module backplane gives completely open rear rack access

Cable management:

70 mm / 2.75" width full-height vertical cable trays to each side of front of rack
70 mm / 2.75" width full-height vertical cable trays to each side of middle of rack
70 mm / 2.75" width full-height vertical cable trays to each side of rear of rack
(see Technical Drawings section)

Option for heavy duty cable management ladders to front of rack for larger scale network cabling applications, part code VCM12

Dust filtering:

Optional air intake dust filters, part code DF12

Door locking:

Key operated lock
Option for high security code-entry lock, part code CEL1

Standards compliance:

Electrical systems meet or exceed BS EN 60950:2000, BS 5733:1995 and ISO 9001-2000 and are compliant ROHS Directive 2002/95 and UL60950-1 (USA).

Electronic subsystems meet or exceed EN 60950-1:2006 “Information Technology Equipment - Safety, Part1: General Requirements” and EN292: Part 1: 1991 “Safety of machinery -basic concepts, general principles for design”. Electronics subsystems are CE- certified, certificate number FTE4412GFM-M00 CE, and are compliant with harmonised international standards IEC60950-1:2001 and UL60950-1 (USA).

Acoustic foams meet or exceed UL94-HF1 “Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances”, (USA) and acoustic barrier materials meet UL94-V0 (USA). Multi-layer composite acoustic materials meet UL94-V0 (USA) and UL94-V2 (USA). Flammability ratings meet or exceed requirements in BS 60950-1:2002 “Information Technology Equipment - Safety” and harmonized international equivalent standards EN60950-1:2001 and IEC60950-1:2001.

Standard Finishes

Finished in hard wearing office-type laminates, with Dark Grey sides and a choice of coloured or wood-effect doors and tops.

11U Server Cabinet Model PSEi11
Server Cabinet Finish Server Cabinet Finish Server Cabinet Finish
Light
Grey
Dark
Grey
Black
Server Cabinet Finish Server Cabinet Finish Server Cabinet Finish
White Ash Natural
Oak
Server Cabinet Finish Server Cabinet Finish Server Cabinet Finish
Light
Oak
Natural
Beech
Steamed
Beech

To view the various finish options, please mouse over your preferred finish swatch to change the main cabinet image.

Accessories

19" Rack Heavy-duty vertical cable management

Heavy-duty vertical cable management fit-out

Where extensive network cabling is being installed in a Kell Systems ComputerVault Pro, this option is recommended. The front cable trays are replaced with columns of steel cable management loops mounted on either side of the front of the 19" rack, enabling tidy and secure management of hundreds of Ethernet cables around patch panels and switch gear in the front of the data cabinet. This option cannot be retro-fitted and is only available at time of first ordering the ComputerVault Pro.

For ComputerVault Pro model PSEi11
Part code VCM12
Number of cable loops 3 per side
19" Rack Horizontal cable management panels

Horizontal cable management panels

For tidy and secure management of cables and jumpers around patch panels and switch gear in the front of the server cabinet.

Part code HCM
Static server rails

Static server rails

Where tower servers are to be installed in a Kell ComputerVault Pro, these simple and inexpensive rails provide an alternative to costly manufacturer´s 19" rack mount conversion kits. Fits modern tower servers of the approx. 450 mm standard height. Please measure the height of your tower server and check with your Kell representative if you are unsure of compatibility.

Part code SSR
19" rack baying kit

Baying kit for linking ComputerVault Pro together

Allows adjacent Kell ComputerVault Pro to be linked together with the cabinets open to each other internally, without compromising the noise reduction performance. Note that baying ComputerVault Pro together reduces the maximum recommended thermal load per cabinet by about 20%, and the thermal load should be distributed evenly between the cabinets. Please refer to the Kell ComputerVault Pro Product Guide for more details, or consult your Kell Systems representative if in doubt. This option can only be retrofitted to v7.6 ComputerVault Pro models delivered from January 2008 onwards.

For ComputerVault Pro model PSEi11
Part code BK12
Kell PSE fan module

Spare Kell ComputerVault Pro fan module

The Kell Systems exhaust fan module is common to all ComputerVault Pro and attaches to the back of the server cabinet with push-fit clips. It can be changed in a couple of minutes with no tools and no requirement for technical knowledge. ComputerVault Pro fan failures are extremely rare, however should you be deploying a Kell ComputerVault Pro in an overseas location to which shipping of spares can take time, a locally-held spare provides restoration in minutes.

Part code KFM
Cantilever 19" rack  equipment shelve

Cantilever equipment shelves

Kell cantilever equipment shelves fix to the front rack posts via 4 x conventional rack screws and cage nuts (not supplied). Depth 400 mm. They provide a suitable rack-mounting platform for smaller non-rack-mounting devices such as modems, routers, switches, tape drives, KVMs etc. They are suitable for use with some mini-desktop pcs, but should not be used to support servers (see Static Server Rails above).

Rack height of shelf 2U 3U 4U
Part code CS2 CS3 CS4
Server cabinet Dust filter

Dust filter pack

Kit includes removable, washable dust filters for all ComputerVault Pro air intake apertures. Easy to retrofit with no tools required. Please note that dust filter packs are standard fit on BladeVault™ cabinets

ComputerVault Pro Model PSEi11
Part code DF12
High security code-entry door lock

High security code-entry door lock

Kell ComputerVault Pro have key-entry tamper locks as standard. This option is for higher security applications and/or where there is concern that keys may get lost.

Part code CEL1
IEC320 8-way

Additional IEC320 8-way PDU kit for model PSEi11UK

8 x surge-protected IEC320 female power outlets
2.9 m trailing lead, terminated with IEC320 female trailing socket
Includes 1.9 m extension cable: IEC 320 male plug to UK standard 3-pin plug


Part code IE8UK
NEMA 8-way PDU

Additional US NEMA 8-way Horizontal PDU kit

8 x surge-protected NEMA 3-pin female power outlets
2.9 m trailing lead, terminated with IEC320 female trailing socket
Includes 1.9 m extension cable: IEC 320 male plug to US NEMA 3-pin plug

Part code NE8USH
Schuko 8-way PDU

Additional Schuko 8-way Horizontal PDU kit

8 x surge-protected Schuko female power outlets
2.9 m trailing lead, terminated with IEC320 female trailing socket
Includes 1.9 m extension cable: IEC 320 male plug to Schuko 3-pin plug

Part code SC8EUH
Schuko 8-way PDU

Additional Schuko 8-way PDU kit for models PSEi11EU

8 x surge-protected Schuko female power outlets
2.9 m trailing lead, terminated with IEC320 female trailing socket
Includes 1.9 m extension cable: IEC 320 male plug to Schuko 3-pin plug

Part code SC8EU
UK 3-pin 8-way PDU

Additional UK 3-pin 8-way Horizontal PDU kit

8 x surge-protected UK 3-pin female power outlets
2.9 m trailing lead, terminated with IEC320 female trailing socket
Includes 1.9 m extension cable: IEC 320 male plug to UK standard 3-pin plug

Part code 3P8UKH

Drawings

PSEi11 Plan Section

PSEi11 Server Cabinet Technical Drawing

PSEi11 External views

PSEi11 Server Cabinet Technical Drawing

PSEi11 side section

PSEi11 Server Cabinet Technical Drawing

Please note reduction in internal cabinet depth in some rack units due to triangular protrusion of Kell exhaust fan module. Very deep servers or other such hardware must be installed above or below Kell fan modules.

Dimension key:
a) 775 mm / 30.5"
b) 800 mm / 31.5"
c) 860 mm / 33.5"
d) 1010 mm / 39.5"
e) Indicates soundproofed cable entry / exit pathway (acoustic materials not shown). The cable port is large enough to accommodate several hundred Ethernet cables and has a removable top cover. The design is such that pre-terminated patch panels can be installed effortlessly, with no need for de-termination and re-termination.

Delivery and Aftercare

Delivery:

All ComputerVault Pro RM are designed to pass through a standard-size doorframe and are normally delivered fully assembled and ready to use. ComputerVault Pro RM can be broken down into component parts where access conditions are constrained. Please consult your Kell Systems representative for details of delivery options in your area.

Warranty:

1 year general warranty against defective workmanship, inclusive of parts and labour
3 years warranty on fan systems

Rack Planning

Please note the following guidelines are for best installation and operation of hardware in Kell’s ComputerVault Pro and ComputerVault Pro RM ranges of cabinets. Specific cabinet sizes are shown for illustration purposes below, but the principles extend to all ComputerVault Pro and ComputerVault Pro RM sizes.

Distribution of thermal load

24U Thernal load

Avoid clustering hot-running devices such as servers, dense RAID arrays and large VoIP switches in one part of the rack. Distribute the thermal load evenly up and down the rack such that each Kell fan module supports an equal amount of the thermal load, or as close to it as possible. Please allow a minimum 1U gap between all hot-running devices.

The cabinet shown in this example is the model PSE24, which has 2 x fan modules. Models PSE12 and PSE18 each have 1 x fan module, and model PSE38 has 3 x fan modules.

Location for very deep servers

24U Server layout

Each fan module has a triangular metal section protruding slightly into the cabinet (please also see side section drawings in technical drawings section). This does not create an issue for installation of most equipment, but to allow for ample cabling space to the rear, deep servers are generally best installed in the rack spaces above and below these triangular metal protrusions.

Side Section Dimensions of PSE24

24U Server Cabinet Technical Drawing     Dimension key:
a) 775 mm / 30.5"
b) 800 mm / 31.5"
c) 860 mm / 33.5"
d) 1010 mm / 39.5"

Baying cabinets together

Baying Cabinets

When the optional baying kit is used to link cabinets together, the rear sections of the cabinets are open to each other as shown here.

Thermal load in bayed cabinets

Distribution in bayed cabinet

When installing hardware in bayed cabinets, distribute hot-running devices evenly between the cabinets as shown.

Floor space requirements:

Individual cabinets are designed to be pushed back flush against a wall. An air space of 200 mm / 8" on both sides of the cabinet is essential for normal operation.

 

Please note that standard Kell Systems ComputerVault Pro as shown herein are not suitable for use with blade servers. Please refer to Kell's BladeVault™ solution for deployment of these types of devices.

Power Specifications

Internal power distribution:

11 x remote-managed IEC320 outlets on rear panel of built in management system, please refer to Remote Management section for full details on power management functions, including remote reboot by device.

ComputerVault Pro RM power input connection:

All Kell ComputerVault Pro RM have power input via an IEC C19 (male) trailing lead for connection to an in-rack UPS, and an extension cable for connection to a wall outlet. User may choose the preferred way to connect. The extension cables are configured as follows:

UK: IEC C20 female trailing socket to standard UK 3-pin plug
Europe: IEC C20 female trailing socket to Schuko 3-pin plug
USA/Canada: IEC C20 female trailing socket to standard US 3-pin plug
Custom: IEC C20 female trailing socket to any user-specified 3-pin plug

Grounding/Earthing:

All equipment installed within a Kell Systems ComputerVault Pro RM should have conventional grounding/earthing via power cables, but unlike conventional metal-case cabinets, the ComputerVault Pro RM itself has no requirement for additional grounding/earthing in the form of ground strapping or pipe earthing etc. The cabinet shell is constructed entirely from non-conductive materials and the rack is completely isolated from outside contact.

Anti-static measures:

No anti-static measures are required in a Kell Systems ComputerVault Pro RM installation. The rack has full electrical isolation and is not susceptible to static build up that can originate in conventional metal racks by contact with artificial carpet or other flooring materials.

Remote Power Management

A single web-based interface provides:-
Full remote power management functions

  • Power to each device in the rack is switchable on/off individually, by remote command
  • Remote management system connects to in-rack UPS or directly to mains power outlet, 220V to 240V
  • 11 x IEC 320 power outlets on rear panel
  • All devices in the rack plug into remote management system
  • Each power outlet has a user-defined device "name" (server1, server2, etc.)

Environmental Monitoring

A single web-based interface provides:-

Climate monitoring, enclosure cooling fan system status, UPS status and intruder detection

  • Air temperature in the room in which ComputerVault Pro RM is installed
  • Air temperature inside enclosure
  • Humidity inside enclosure
  • Unauthorised access to enclosure (doors opened without permission, etc.)
  • Total mains current draw measurement of ComputerVault Pro RM and all systems installed
  • UPS status (AC power is coming from “main” or “battery”) when used with UPS devices from APC
  • ComputerVault Pro RM cooling fan status in each enclosure exhaust fan module ("OK" or "Fault")

Real-time alerts by email to your pc and/or PDA

  • Temperature in ComputerVault Pro RM: 3 x Administrator-defined states, "normal", "warning" and "critical"
  • Unauthorised access to ComputerVault Pro RM (doors opened, cabinet broken into, etc.)
  • Failure of ComputerVault Pro RM cooling fan systems, with advance warning of any fan performance degradation
  • Power failure to UPS (alerts if UPS has switched to battery power)
  • Each ComputerVault Pro RM in the network may be assigned a local "name" (Bristol, York, etc)
  • Each ComputerVault Pro RM in the network reports its “name” in all alert messages

All intelligence is contained in ComputerVault Pro RM. No software is needed at the management end, unless the administrator wishes to install third party software to convert alarm messages to SMS or pager formats.